When a town or city lights a road, it is not enough for the lights to simply switch on at night. The road needs a certain amount of light, spread evenly enough that drivers and pedestrians can see clearly and safely. Road lighting standards exist to define exactly that. For municipalities planning solar street lighting, understanding the basics of these standards is the difference between a project that passes inspection and one that leaves residents complaining about dark streets.
This article explains the basics of road lighting standards, with a focus on EN 13201, and how they apply to solar street lighting projects.
Why Road Lighting Standards Matter
Without a standard, “enough light” is a matter of opinion. One contractor may space poles every 40 metres, another every 25, and both may claim their design is fine. A lighting standard replaces opinion with measurable targets: the average light level on the road, how evenly it is spread, and how much glare drivers are allowed to experience.
Standards also protect the municipality. A design that meets a recognised standard is easier to defend to councillors, funders and auditors, and it gives the authority a clear benchmark for accepting or rejecting the finished work.
What Is EN 13201?
EN 13201 is the European standard for road lighting. It is widely used in Europe and is also referenced in many international and development-bank funded tenders. It sets out lighting classes for different types of road and explains how to calculate and measure the results. Other regions use similar frameworks, such as CIE 115 internationally or IESNA guidance in North America.
A detailed explanation of these frameworks, and how they compare, is available in this guide to EN 13201 and IESNA road lighting standards.
Lighting Classes in Simple Terms
EN 13201 groups roads into lighting classes. In simple terms:
- M classes apply to roads used mainly by motorised traffic, such as main roads and highways. They focus on how bright the road surface looks to drivers.
- C classes apply to conflict areas, such as junctions, roundabouts and busy shopping streets, where traffic streams meet.
- P classes apply to pedestrian areas, cycle paths and residential streets where walkers and cyclists are the main users.
Within each group, a lower number means a higher requirement. Choosing the right class for each road is the first and most important step in any lighting design.
How Standards Shape a Solar Project
For grid lighting, choosing a slightly higher class than necessary mainly adds to the electricity bill. For solar lighting, it changes the size of every system: more light needs more LED power, which needs a larger solar panel and battery on every pole. Over hundreds of poles, that adds up quickly.
The standard therefore guides three key decisions:
- Luminaire power and optics: enough light, distributed correctly across the road.
- Pole height and spacing: tall enough and close enough to reach the required uniformity.
- System sizing: panels and batteries that can deliver that light every night, including the cloudiest weeks of the year.
Proving Compliance
Municipalities should ask for proof that a design meets the chosen class. The usual evidence is a lighting calculation, often produced in software such as DIALux, that models the actual road with the proposed luminaire, height and spacing, and shows the calculated values against the required ones. Photometric files for the exact luminaire make the calculation verifiable.
After installation, measurements on site can confirm that the lights perform as designed. Including this step in the contract gives the authority a clear way to accept the work.
Common Mistakes Municipalities Make
- Not choosing a lighting class at all, so every bidder designs to a different target.
- Choosing a class that is higher than the road needs, which inflates the cost of every solar system.
- Accepting lumen figures from a datasheet instead of a calculation for the real road.
- Sizing solar systems for an average day instead of the worst month, so the lights cannot maintain the class through the rainy season.
- Forgetting footpaths and crossings, which often need their own class.
Bringing It Into the Tender
The simplest way to use a standard is to write it into the tender. State the lighting class for each road, ask for a lighting calculation and photometric files with every bid, and require system sizing for the worst month. This turns the standard from a technical document into a fair, comparable requirement for all bidders. The full path from survey and design to tender and handover is explained in this guide to planning a government solar street lighting project.
Frequently Asked Questions
Do solar street lights have to meet the same standards as grid lights?
Yes. A road lighting standard describes the light the road needs, not how the light is powered. A solar street light must reach the same lighting class as a grid-powered light on the same road.
Is EN 13201 only for Europe?
It was written for Europe, but many projects elsewhere use it, especially when they are financed by international lenders or designed by European engineers. Always follow the standard named in the national regulations or the funder’s requirements.
Who decides the lighting class for a road?
Usually the road authority or its lighting designer, based on the road’s traffic, speed, users and surroundings. The class should be fixed before any design or tender starts.
Can a small town use a lighting standard without a lighting engineer?
Yes. Many solar street light manufacturers provide the lighting calculation as part of their project support. The town only needs to state the road types and the class it wants, then check that each offer includes a calculation for those roads.
Final Thoughts
Road lighting standards may look technical, but their purpose is simple: make sure every road has the light it needs, no more and no less. For municipalities investing in solar street lighting, choosing the right class, asking for a proper lighting calculation and sizing the solar systems for the worst month are the three steps that turn a standard into safe, well-lit streets.